Refine Your Search

Topic

Search Results

Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification For

2016-10-16
HISTORICAL
AS23053
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy

2011-08-11
HISTORICAL
AS81044A
This specification covers single conductor electric wires made as specified in the applicable specification sheet with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the specification sheet.
Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, Or Polyarlyene Insulated, Copper Or Copper Alloy

2021-12-02
WIP
AS81044C

AS81044 covers single conductor electric wires made as specified in the applicable detail specification with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the detail specification.

Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarlyene Insulated, Copper or Copper Alloy

2004-06-21
HISTORICAL
AS81044
This specification covers single conductor electric wires made as specified in the applicable specification sheet with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the specification sheet.
Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarylene Insulated, Copper or Copper Alloy

2019-07-08
CURRENT
AS81044B
AS81044 covers single conductor electric wires made as specified in the applicable detail specification with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the detail specification.
Standard

Dimensional Life of Heat-Shrinkable Sleeve

2022-05-02
CURRENT
AIR7930
This SAE Aerospace Information Report provides additional information and background in regard to the dimensional life of a heat-shrinkable sleeve. The term dimensional life is newly introduced in AS23053 to relate to the dimensional stability instead of the material stability often associated or referred to as the “shelf life.” When the material exceeds such shelf life, it becomes harmful or non-functional.